Firefighters' portable radios may fail at high temperatures

Wednesday, 17 December, 2014

New test results from the US National Institute of Standards and Technology (NIST) confirm that portable radios used by firefighters can fail to operate properly within 15 minutes when exposed to temperatures that may be encountered during firefighting activities.

Performance problems with portable radios have been identified by the National Institute for Occupational Safety and Health as contributing factors in some firefighter fatalities.

All seven of the firefighter portable radios tested by NIST failed to perform properly within 15 minutes when exposed to temperature levels encountered in ‘fully involved’ fires, as when all the contents in a room or structure are burning.

Four of the handheld radios stopped transmitting, and three experienced significant ‘signal drift,’ rendering them unreliable for communication.

The failures occurred while the radios were subjected to a temperature of 160°C, termed Thermal Class II conditions (see NIST Technical Note 1474 at http://fire.nist.gov/bfrlpubs/fire06/PDF/f06001.pdf).

The temperature is representative of a fully involved fire or conditions outside a room when its contents burst into flames simultaneously, a phenomenon known as flashover.

During the post-test cool-down period, three of the radios did not recover normal function.

Portable radio in a test rig

A portable firefighter radio is instrumented for testing in a NIST-designed apparatus that consistently creates thermal conditions representative of typical fire environments. Credit: NIST

Funded by the US Department of Homeland Security, the NIST tests further ongoing work to develop performance standards for firefighter portable radio equipment, which includes radios, wearable combinations of speakers and microphones, and related items.

The existing standard provides only general guidance - that portable radios “be manufactured for the environment in which they are to be used”.

NIST researchers are furnishing their test data and performance measurements to the US National Fire Protection Association, which is developing a performance standard for portable radios used by emergency personnel.

As important, the NIST team designed a prototype apparatus to electronically control testing equipment intended to consistently create thermal conditions representative of typical fire environments.

All radios tested by NIST performed reliably when exposed to a temperature of 100°C for 25 min, or Thermal Class I conditions, akin to a small fire in a room or fighting a fire from a distance.

No tests were conducted under more extreme fire conditions (Thermal Classes III and IV).

“Realistic and reliable performance tests provide clear design targets for portable radio manufacturers,” explained NIST fire protection engineer Michelle Donnelly. “Standards incorporating these tests provide firefighters with the assurance that their equipment will perform as expected under specified thermal conditions.”

For more information, see MK Donnelly, WF Young, and D Camell, Performance of Portable Radios Exposed to Elevated Temperatures (NIST Technical Note 1850); September 2014.

Related News

Critical Comms leaders head to Wellington for Comms Connect NZ

The 11th edition of Comms Connect NZ will take place at Tākina Wellington on 27–28 May.

ACMA updates its Telco consumer complaints report

The latest consumer complaints report highlights increased wait times and escalations.

Comms Connect NZ early bird registration ends soon

Early bird registration for the 2026 Comms Connect NZ conference closes on 1 May.


  • All content Copyright © 2026 Westwick-Farrow Pty Ltd