Vitrek electrical safety analyser
The Vitrek V5 electrical safety analyser combines AC and DC dielectric strength testing, insulation resistance testing, leakage current and high-current ground bond testing in accordance with UL, CSA, IEC and TUV standards.
The analyser can be used as a tool in engineering and development or in production and is suitable for multipoint measurement through its in-built 8-point scanner.
A bidirectional RS232 port permits automation of testing and an optional GPIB port (talker/listener) is also available.
Dielectric strength can be measured to 5 kV AC with a maximum current of 40 mA, and to 6 kVDC with a maximum current of 10 mA. Insulation resistance can be measured to 10 GΩ at voltages to a 1000.
Ground bond testing takes place with a maximum current of 42 A and a maximum resistance of 600 mΩ.
The instrument incorporates 10 programming sequences of 16 steps maximum per sequence including digital ramp and dwell times and a safety fault interrupt circuit.